Alarm Lists
Alarm Description Port Number Alarm ID Source Severity
Sequence Number Invalid (SNI)
failure
Garbled AAL1 SAR-PDU headers.
Far-end terminal equipment might
be configured erroneously (non-
standard transmission parameters).
1 01120027 G.703 I/O major
Lost Or Misinserted Cells (LMC)
failure
Inconsistent ATM cell stream.
Network ATM switching functionality
might be unreliable.
1 01120028 G.703 I/O major
TS Sync Loss Error (TSLE)
failure
TS synchronization loss.
Transmission might not contain a
valid MPEG-2 Transport Stream.
1 01120029 G.703 I/O major
Loss Of Lock (LOL) failure
Receive clock recovery PLL not
locked. Transmission PDH carrier
(E3/DS3) might have changed.
1 0112002A G.703 I/O major
DS3 Framing Format Mismatch
(DS3FM) failure
Wrong DS3 framing format.
Transmission framing format
(M13/C-bit) might have changed.
1 0112002B G.703 I/O major
Unsupported Transmission
Format failure
Transmission Format Auto detection
(TFA) timed out. Input signal might
not be valid or supported.
1 0112002C G.703 I/O major
Transmit Driver Overload failure
Short circuit detected on the output.
Please check the G.703 Output port.
Cable might be faulty.
1 01120030 G.703 I/O major
E.8 Alarms List ā GPI Card
The following table lists the alarm and failure identifiers generated by the GPI option
card.
Table E.9 Alarm List ā GPI Card
Alarm Description Port Number Alarm ID Source Severity
Over Temperature Warning
Failure to take action may cause
permanent damage to the unit.
Please check the fans are working
correctly, and that the ambient
temperature is not excessive.
0 00130001
Data & GPI
Module
minor
Over Temperature
Failure to take action may cause
permanent damage to the unit.
Please switch it off and refer to
Customer Support.
0 00130002
Data & GPI
Module
critical
Invalid Parameter
Invalid Parameter received by the
Data & GPI Module. Please see
Video Encoder status for a more
detailed description of the error.
0 00130003
Data & GPI
Module
critical
Module Error
Option Card Error. Please see log
for a more detailed description of the
error.
0 00130004
Data & GPI
Module
critical
Power On Self Test Failure
At least one start-up test has failed.
Problems may be experienced with
the normal operation of the unit.
0 00130005
Data & GPI
Module
critical