Web GUI Control
EN/LZT 790 0023/1 R16A
5-27
5.4.4.4.2 Load Stored Configurations (Not Supported in this Release)
It is possible to use the GPI input pins to trigger the loading of any of the 64 stored
configurations on the unit. The selection of the stored configuration is made by
configuring 6 of the GPI input pins as a binary representation of the store number
while a 7
th
pin provides the toggle to action the loading of the configuration.
When a GPI Input Pin Mode is set to Load Stored Config the next 6 pins are
automatically configured to the same setting. The lowest pin number (originally
selected) is the LSB of the store number. The highest pin number is the GPI trigger
to load the selected configuration.
Figure 5.24 Load Stored Configurations
For example: If 'GPI Input Pin 3' is set to ‘Load Stored Config’ and the following pins
are set as follows
GPI Input Pin 3 0 LSB
GPI Input Pin 4 0
GPI Input Pin 6 1
GPI Input Pin 7 0
GPI Input Pin 8 1 MSB
When GPI Input Pin 9 is toggled the configuration in store 40 is loaded.
When a GPI input pin mode is selected, the splicing setup options become available
by expanding the appropriate GPI Input Pin n Setup folder. The parameters are
listed below.