Technical Specification
Table B.36 Data Input Specification
Item Specification
Safety status SELV
Connector designation DATA IN
Connector type D-type, 9-way, Female
GPI Input 1200, 2400, 4800, 9600, 19200, 38400 baud
B.4 Environmental
B.4.1 Environmental Conditions
The AVP is for use in non-hostile environments, (i.e. designed for indoor use only
with no protection against dust or water ingress).
Table B.37 Environmental Conditions
Operational Specification
Temperature
–10ºC to +50ºC (14ºF to 122ºF) ambient with free air-flow. It may require a 10
minute warm-up period before all clocks are within specification if the ambient
temperature is less than 0ºC
Humidity 0% to 90% (non-condensing)
Cooling Requirements Cool air input from left side of unit, exhaust from right side of unit.
Handling Movement Designed for stationary or fixed use when in operation.
Transportation (Packaged)
Temperature -40°C to +70°C (-40°F to +158°F)
Humidity 0% to 90% (non-condensing)
Storage
Temperature -25°C to +70°C (-13°F to +158°F)
Humidity 0% to 90% (non-condensing)
The product requires no special handling or packaging other than normal
procedures for Ericsson equipment and is suitable for lifting by one person.