Alarm Lists
E-6
EN/LZT 790 0023/1 R16A
Alarm Description Port Number Alarm ID Source Severity
Over Temperature Warning
Failure to take action may cause
permanent damage to the unit.
Please check the fans are working
correctly, and that the ambient
temperature is not excessive.
0 00000442 Base Unit minor
Over Temperature
Failure to take action may cause
permanent damage to the unit.
Please switch off and refer to
Customer Support.
0 00000443 Base Unit critical
Power On Self Test Failure
At least one start-up test has failed.
Problems amy be experienced with
the normal operation of the unit.
0 00000444 Base Unit minor
+12V A Failed
+12V A rail has failed. Please check
supply or contact Customer Support.
0 00000445 Base Unit warning
+12V B Failed
+12V B rail has failed. Please check
supply or contact Customer Support.
0 00000446 Base Unit warning
Real Time Clock
The Real-time clock has failed. The
time/date will not be stored between
power-ups.
0 00000447 Base Unit minor
NTP Server Response Timeout
The unit could not contact the NTP
Server. The time/date will drift over
time.
0 00000448 Base Unit warning
Internal Hardware Issue
An Internal Hardware Issue has
occured. The system may not
function properly.
0 00000449 Base Unit minor
Host Build Version Mismatch
Host software is not at an officially
released version. Host function may
not be affected.
0 0000044A Base Unit minor
System Clock Not Locked
The system 27 MHz VCXO is not
locked. Check if the Mux SCR
Source is valid.
0 0000044B Base Unit minor
Chassis Identity Not
Programmed
The chassis identity of the host
could not be read correctly.
0 0000044C Base Unit minor
Selected Mux SCR Source is not
present
Selected Mux SCR Source could not
be detected. Check if the Sync Card
is plugged in.
0 0000044D Base Unit minor
Host Identity Not Programmed
The host identity could not be read
correctly.
0 0000044E Base Unit major
Uncontrolled release
This combination of host and option
card software is not officially
supported. This may lead to
unexpected behavior.
0 0000044F Base Unit minor
No identity license
This unit has not been licensed with
an identity.
0 00000450 Base Unit critical
TS NIT is not valid
At one or more TS the Send
extended NIT (SIRG) parameter is
switched On, and one or more of the
parameters Operator, Longitude or
Latitude have invalid values.
0 00000680 Base Unit major
Unsupported Option Card
The Option Card in Slot 1 is not
supported with this software release.
This may lead to unexpected
behaviour.
o 00000451 Base Unit major