EasyManua.ls Logo

Ericsson SmartEdge 600 - Page 66

Ericsson SmartEdge 600
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SmartEdge 600 Router Hardware Guide
Table 41 Output Fields for the show hardware Command with the detail Keyword
Field Description
SFP Transceivers—Ethernet line cards:
FX / MM—Short reach transceiver, multimode fiber.
LX10 / SM—Long reach transceiver, single-mode fiber.
SX / MM—Short reach transceiver, multimode fiber.
LX / SM—Long reach transceiver, single-mode fiber.
ZX / SM—Extended long reach transceiver, single-mode fiber.
T / Cat5—Copper-based transceiver.
CWDM / SM—Coarse wavelength-division multiplexing (CWDM) transceiver, single-mode fiber.
DWDM / SM—Dense wavelength-division multiplexing (DWDM) transceiver, single-mode fiber.
SFP / Media type
SFP transceivers—SONET/SDH OC-n (OC-48c/STM-16c, OC-12c/STM-4c, and OC-3c/STM-1c)
cards:
SR / SM—Short reach transceiver, single-mode fiber.
SR / MM—Short reach transceiver, multimode fiber.
IR / SM—Intermediate reach transceiver, single-mode fiber.
LR / SM—Long reach transceiver, single-mode fiber.
SFP Serial No nnnnnnnnnn—Unique identifier for this transceiver; 10 alphanumeric characters.
Slot slot—Slot number for this unit.
N/A—No slot number for this unit.
SlipFpga file rev SLIP FPGA revision; applicable to the SmartEdge 100 I/O carrier card functions only (slot 1).
SFP Serial No Small Formfactor Pluggable serial number
SpiFpga file rev System Packet Interface File revision.
SpiFpga rev System Packet Interface Fpga.
SXC id ID of the SONET cross-connect (SXC) ASIC on a controller card; the SXC cross-connects traffic
between some line cards.
SysFpga rev System FPGA revision and file revision; N/A or not displayed if not applicable for this line card.
Temperature Temperature condition and actual temperature reading in degrees Celsius:
Cold—Temperature is colder than normal.
Extreme—Temperature is much hotter than normal.
Hot—Temperature is hotter than normal.
N/A—Temperature does not apply to this unit.
Normal—Temperature is within normal operating range for this unit.
Table 42 lists descriptions of each temperature condition.
Table 43 lists temperature ranges for card types.
TxPwrMin[dbm]
(2)
TxPwrMax[dbm]
-nn.nn—Transmitter optical output power (minimum and maximum) for the version of the SFP
transceiver installed in this port.
60 27/153 30-CRA 119 1170/1 Uen A | 2010-04-09

Table of Contents

Related product manuals