Table 55 Controller Card Alarms
Description Severity Probable Cause Service Affecting
Real-time clock failure Major RealTimeClockFailure Yes
Redundancy link fail Major OperationFail Yes
(1) This alarm is suppressed if the system has a single controller card and has been configured using the system
alarm command (in global configuration mode) with the >redundancy suppress construct.
3.11.4 SSE Card Alarms
Table 56 SSE Card Alarms
Description Severity Probable Cause Service Affecting
NFS server service down Major reinitialized Yes
Disk type mismatch Warning replaceableUnitTypeMismatch No
CPU Crash Critical processorProblem Yes
3.11.5 SSE Disk Alarms
Table 57 SSE Disk Alarms
Description Severity Probable Cause Service Affecting
Hard disk health degraded Minor replaceableUnitProblem No
Hard disk failed Major diskFailure Yes
Hard disk missing Major replaceableUnitMissing Yes
Hard disk not supported Major replaceableUnitTypeMismatch Yes
Hard disk out of service Minor diskFailure No
Hard disk voltage failure Major diskFailure Yes
Hard disk overheating: extremely hot Major diskFailure Yes
Hard disk overheating: temperature hot Minor diskFailure No
Hard disk reading test failur Major diskFailure Yes
Hard disk power-on diagnostic failed Major diskFailure Yes
3.11.6 SSE Group Alarms
Table 58 SSE Group Alarms
Description Severity Probable Cause Service Affecting
SSE group manual switch in progress Major operationNotification Yes
SSE group auto switch in progress Major configurationOrCustomisationError Yes
SSE group switch completed Warning configurationOrCustomisationError No
SSE group switch failed Major operationNotification Yes