Hardware Control and Troubleshooting
Table 54 Line Card Alarms
Description Severity Probable Cause Service Affecting
Loss of backplane clock Major ReplaceableUnitProblem Yes
Software download completed Warning OperationNotification Yes
Software download failed Warning OperationFailure Yes
Synchronization failure Critical TimingProblem Yes
Voltage failure detected Major ReplaceableUnitProblem Yes
3.11.3 Controller Card Alarms
Table 55 Controller Card Alarms
Description Severity Probable Cause Service Affecting
Backup fail: peer dead
(1)
Major ReplaceableUnitProblem Yes
Controller auto switch completed
(1)
Major OperationNotification Yes
Controller code mismatch Major ReplaceableUnitTypeMismatch Yes
Controller exerciser switch failed
(1)
Major OperationFailure Yes
Controller fail Critical ReplaceableUnitProblem Yes
Controller forced switch requested
(1)
Major OperationNotification Yes
Controller manual switch requested
(1)
Major OperationNotification Yes
Controller missing
(1)
Critical ReplaceableUnitMissing Yes
Controller overheating Major ReplaceableUnitProblem Yes
Controller power-on diagnostic failed Major ReplaceableUnitProblem Yes
Controller switch completed
(1)
Major OperationNotification Yes
Controller switch failed
(1)
Major OperationFailure Yes
Controller temperature critical Major ReplaceableUnitProblem Yes
Controller temperature hot Minor ReplaceableUnitProblem Yes
Controller type mismatch Major ReplaceableUnitTypeMismatch Yes
Diagnostic test fail Major ReplaceableUnitProblem Yes
Local backplane inventory fail Major ReplaceableUnitProblem Yes
Local fan tray inventory fail Major ReplaceableUnitProblem Yes
Local inventory fail Major ReplaceableUnitProblem Yes
Nonvolatile memory fail Major CorruptData Yes
Peer controller card type incompatible
(1)
Major ReplaceableUnitProblem Yes
Peer inventory fail
(1)
Major ReplaceableUnitProblem Yes
Peer shared format mismatch
(1)
Major ReplaceableUnitProblem Yes
Peer Sonet/Sdh mode incompatible
(1)
Major ReplaceableUnitProblem Yes