Table 76 Display Results from ODD Sessions
Task Command
Display results for the standby controller card.
show diag on-demand standby
Display results for the last n sessions. The latest session
is displayed first. Up to 100 sessions can be listed.
show diag on-demand history n
Table 77 Status Descriptions for an ODD Session
Session Status Description
Aborted Session was terminated by the user or by the standby controller card being
removed.
Incomplete At least one of the requested tests could not be run.
In-Progress Session is currently in progress.
n Failures Session was completed with a number of test failures.
Passed All tests passed.
Table 78 Status Descriptions for a Test
Test Status Description
Aborted Test was started but terminated by the standby controller card being removed.
Failed Test ran and failed.
Not Run Test has not yet run (initial state).
Passed Test ran successfully.
Running Test is currently in progress.
Skipped Test could not be run; for example, the part revision is earlier than the required
minimum version or no file found.
In general, if a unit fails to pass a test, you should replace it or make
arrangements for its replacement. Contact your local technical support
representative for more information about the results of a failed test.
If the version of the Sys FPGA on a line card is not 0x7 or later, the voltage
check, temperature check, and bus tests cannot be run; they are skipped, and
the session status is reported as “Incomplete”. To resolve the problem, enter
the
show hardware command (in any mode) with the card and detail
keywords to display the FPGA version in the SysFpga field. To upgrade this
FPGA to the latest version, contact your local technical representative or the
Ericsson TAC.
3.13.4 Clear Results from ODD Sessions
To clear the results from one or more ODD sessions, perform one of the tasks
listed in Table 79; enter all commands in exec mode.