6.11 Start type
There are two options for start type:
S Direct start, means that the travel speed starts when the arc is struck.
S Scrape start, means that the travel speed starts at the same time as wire feed.
Start type is selected in the weld data setting menu under start data.
6.12 Wire creep start
Wire creep start is used to set the desired creep speed on the electrode motor upon
startup.
If, for example, 50 is set in the menu a creep speed of 50 cm/min is obtained.
Preset value ”AUTO” gives a creep speed calculated from the set values.
Wire creep speed is set in the weld data setting menu under start data.
6.13 Start phases
When welding special wire or material, it may be necessary to create your own start
sequence. The start sequence can affect the appearance of the weld pool.
The following can be set for Start
phase1 ON
The following can be set for Start
phase2 ON
S Time s
Time for welding in phase 1.
S Time s
Time for welding in phase 2.
S Arc voltage %
In percent of set voltage
S Arc voltage %
In percent of set voltage
S Wire feed %
In percent of set wire feed
S Wire feed %
In percent of set wire feed
S Welding current %
In percent of set welding current
S Welding current %
In percent of set welding current
S Travel speed %
In percent of set travel speed
S Travel speed %
In percent of set travel speed
Start phases are set in the weld data setting menu under start data.
6.14 Max Open Circuit Voltage (OCV)
ON means that OCV can be set.
OFF means that OCV is set to the set value for welding voltage.
OCV is set in the weld data setting menu under start data.
6.15 Flux postflow
This controls the time during which flux flows after the arc is extinguished.
Flux postflow is set in the weld data setting menu under stop data.