7.7 Edit
To edit the content of a weld data set, proceed as follows:
Mark the memory posi-
tion you wish to
change. Press 2ND
FUNCT and then EDIT.
WELD DATA MEMORY
1
2
3
4
5 (SAW)
6
7
SAW: CA: FE SOLID: 3.0 mm
30.0 V: 450 A: 50 cm/min
COPY
EDIT
2ND
FUNCT QUIT
Part of the main menu is displayed and the menu shows the symbol which
means that you are in an editing mode.
Press SET and make
the relevant changes.
SAW
REGULATION TYPE CA
WIRE TYPE SS FLUX CORED
WIRE DIMENSION 2.0 mm
SET QUIT