− 47 −
bi24d1ea
9.3.4 Copy and paste files
Select the file that is to be copied and press ALT.
Select COPY and press ENTER.
COPY
PASTE
DELETE
RENAME
NEW FOLDER
Position the cursor in the folder in which the copied file is to be located and press
ALT.
Select PASTE and press ENTER.
COPY
PASTE
DELETE
RENAME
NEW FOLDER
The copy is saved as Copy of plus the original name, e.g. Copy of WeldData.awd.
9.4 Setting limit editor
Main menu Tools Setting limit editor
In this menu you set your own max. and min. values for various welding methods.
The limits cannot be above or below the values for which the power source is
dimensioned. There are 50 storage points. Select the row for an empty storage point
and press ENTER. Select process by pressing ENTER and select the welding
process using the positioning knob and press ENTER.
The maximum and minimum values for arc voltage, wire feed speed, travel speed
and welding current can be selected for all processes.
EDIT LIMITS
PROCESS SAW
VOLTAGE MIN 17.0
VOLTAGE MAX 47.0
WIRE SPEED MIN 50
WIRE SPEED MAX 970
TRAVEL SPEED MIN 100
TRAVEL SPEED MAX 2400
CURRENT MIN 70
CURRENT MAX 1500
STORE
DELETE QUIT
GB