− 49 −
bi24d1ea
In the dialogue box, you are asked if you want to store the selected storage point.
Press YES to save the value. The storage point’s values can be seen under the line
at the bottom.
MEASURE LIMITS
1 − SAW
2 − GMAW
3 −
4 −
5 −
6 −
7 −
0.0 − 46.9 Volt , 0 − 2495 cm/min
3 − 994 cm/min , 3 − 990 Amp
5 − 500 kJ/min
QUIT
With the AUTO soft key, the parameters are set automatically according to the most
recently used measurement values.
When asked if the measurement values are to be set automatically, press NO or
YES and then STORE if the setting is to be retained.
9.6 Production statistics
Main menu Tools Production statistics
The production statistics will keep track of the total arc time, the total amount of
material and the number of welds since the most recent reset. They will also keep
track of the arc time and the amount of material used in the most recent weld. For
information purposes, the melted wire material per length unit that has been
calculated and when the most recent reset occurred are also displayed.
PRODUCTION STATISTICS
LAST WELD TOTAL
ARCTIME 0s 0s
CONSUMED WIRE 0g 0g
BASED ON 1g/m
NUMBER OF WELDS 0
LAST RESET 081114 08:38:03
RESET UPDATE
QUIT
GB