48
S2 Serial Number
The serial number for the fire can be found in two places. The first is in the battery compartment
of the wireless remote under the batteries. The second is on the data sticker on the chassis
under the firebox on the left hand side.
S3 Checking Operating Pressure
See section E14 on page 31 of this manual.
S4 Cleaning the Log Set and Glass
NEVER RUB THE FASCIA. The outside of the fascia’s must only be cleaned with a clean damp
cloth, dry o after cleaning. The high temp silver powder coating that is used on Escea fascia parts
contains certain amounts of aluminium that when rubbed too hard will oxidise leaving a black smudge
that cannot be removed. Always clean when cold.
This is a service procedure that will need to be carried out whenever soot builds up on logs and/
or inside of glass. If soot build up becomes excessive or regular then one of the following actions
may be required;
• Reset gas pressure, pressure may be too high;
• Reposition log set so that front edge of each log is just behind each row of holes in burner
top;
• Clear any blockage from primary air port of burner;
• Check flue tube is not damaged or disconnected.
For diagrams and further info on removing your fascia, reverse the steps found in section F on
page 34.
• Remove fascia bottom panel by pulling it o the magnets that retain it to the fire. Remove
the 2 screws holding the inner fascia, lift o the inner fascia by pulling the base of the inner
fascia out and lifting it up and o.
• Unscrew the side and top glass retainers and remove them. Take care that the glass does
not fall forwards at this stage.
• Lift out glass and place it carefully aside.
• Take out fuel bed and gently brush any soot from log with a soft hearth brush. The burner
tops can be vacuumed to remove any excess material.
• Clean the inside and outside of glass with normal glass cleaning products. Use a CLEAN
DRY cloth only. Stubborn marks may be cleaned with a ceramic glass cleaner.
• Replace in opposite order and test run heater.
S5 Servicing the Horizontal Powerflue Wall Terminal
If the Horizontal Powerflue Wall Terminal needs servicing, the fan can be accessed from the
outside of the installation.