Hardware Description16
Ethernet switch with a 10/100 MBit/s data rate:
• One host port (upstream)
• Three ports for compatible modules (downstream)
• Can be cascaded up to 15 modules
• Status display for every port
• Automatic standby function
• Precise synchronization of all connected modules and their measure-
ment channels
Two independent CAN interfaces:
• CAN High Speed (max. 1 MBaud)
• Transceiver (Physical layer): Philips TJA1040
• CAN IP Controller
• CAN protocols
– CAN V2.0a (Standard Identifier with 11-bit)
– CAN V2.0b (Extended Identifier with 29-bit)
• Baud rate can be configured by software
Two independent LIN interfaces:
• LIN specification LIN V2.1
• Operating mode Slave (monitoring)
• Transceiver (Physical layer): MCZ33661EF
Additional features of the module:
• Module suitable for use in automotive applications; suitable for use in
the development environment and in the vehicle on test drives.
– Channels galvanically isolated from each other, from the device
ground and from the supply voltage
– Not sensitive to environmental conditions (temperature, EMC)
– Wide supply voltage range
– High mechanical stability and durability
• Part of the ETAS Tool Suite
For the complete technical data of the ES511.1, refer to the chapter "Technical
Data" on page 37.
Manual.book Seite 16 Montag, 13. Juli 2009 6:24 18