Techni c a l Data38
5.1.3 Mechanical Data
5.2 System Requirements
5.2.1 Hardware
Operation of the ES511.1 requires a power supply voltage of 6 V to 32 V DC.
5.2.2 Ethernet Interface of the PC
A PC with a free Ethernet interface (10/100 Mbit/s, Full Duplex) with an RJ-45
connection is required. Ethernet interfaces realized by an additional PCMCIA
network card in the PC must have a 32-bit data bus (Card Bus).
The manufacturers of the network cards have different names for this func-
tion.
Example: “Link down Power saving”
5.2.3 Supported Applications and Software Requirements
Software in the following versions is required to configure and control the
ES511.1 and for data acquisition purposes:
Dimensions (H x W x D) 52 mm x 169 mm x 107 mm /
2.05 in x 6.65 in x 4.25 in
Weight 520 g / 1.43 lb
Note
It is imperative you disable the function which automatically switches to
power-saving mode on your PC network card when there is no data traffic
on the Ethernet interface!
Support in
Application Software
Inter-
face
Application Classifi-
cation
1)
INCA INTECRIO ASCET-RP
ETH XCP on Ethernet MC V6.2.1 - -
Manual.book Seite 38 Montag, 13. Juli 2009 6:24 18