Appendix: Troubleshooting Problems 57
Select the Advanced tab. If the property
Autosense is included, deactivate it also.
•Click OK to apply the settings.
Cause: Automatic disruption of network connection
It is possible after a certain period of time without data traffic that the network
card automatically interrupts the Ethernet connection. This can be prevented
by setting the registry key autodisconnect.
To set the registry key autodisconnect:
Open the Registry Editor.
Select under
HKEY_LOCAL_MACHINE\SYSTEM\
ControlSet001\Services\lanmanser
ver\parameters the Registry Key
autodisconnect and change its value to
0xffffffff.
8.3.3 Personal Firewall blocks Communication
Cause: Permissions given through the firewall block ETAS hardware
Personal firewalls may interfere with access to ETAS Ethernet hardware. The
automatic search for hardware typically cannot find any Ethernet hardware at
all, although the configuration parameters are correct.
Certain actions in ETAS products may lead to some trouble if the firewall is not
properly parameterized, e.g. upon opening an experiment in ASCET or search-
ing for hardware from within INCA or HSP.
If a firewall is blocking communication to ETAS hardware, you must either dis-
able the firewall software while working with ETAS software, or the firewall
must be configured to give the following permissions:
Outgoing limited IP broadcasts via UDP (destination address
255.255.255.255) for destination ports 17099 or 18001
Incoming limited IP broadcasts via UDP (destination IP
255.255.255.255, originating from source IP 0.0.0.0) for destination
port 18001
Directed IP broadcasts via UDP to the network configured for the ETAS
application, destination ports 17099 or 18001
Outgoing IP unicasts via UDP to any IP in network configured for the
ETAS application, destination ports 17099 through 18020