Technical Data 37
5 Technical Data
The “Technical Data” chapter contains a summary of all technical data and the
pin assignments of the ES511.1 module.
5.1 General Data
5.1.1 Fulfilled Standards and Norms
The module adheres to the following standards and norms:
The module is designed only for use in industrial environments in accordance
with EN 61000-6-4. When using the module outside of industrial environ-
ments avoid possible radio disturbances by additional shielding measures!
5.1.2 Environmental Conditions
Norm Test
EN 61326 Electrical equipment for measure-
ment, control and laboratory use -
EMC requirements
EN 61000-6-2 Immunity (industrial environments)
EN 61000-6-4 Emission standard (industrial environ-
ments)
WARNING!
This is a class A product. In a domestic environment this product
may cause radio interference in which case the user may be
required to take adequate measures.
Operating temperature range -30 °C to +70 °C
-22 °F to +158 °F
Storage temperature range
(module without packaging)
-30 °C to +85 °C
-22 °F to +185 °F
Manual.book Seite 37 Montag, 13. Juli 2009 6:24 18