36 05 2013 4365 00
display
This group of functions controls all the parameters re-
lated to the display.
lingua
E’ possibile scegliere in quale lingua, tra tutte quelle pre-
viste dal software, visualizzare i messaggi sul display.
promotional message
enabling the promotional message
This function allows you to enable the display of the
promotional message which has been set
promotional message setup
The message of 5 rows of 16 characters can be com-
posed by using the keys
and
for scrolling the avail-
able characters.
By pressing the conrmation key
the rst character
that can be modied ashes.
The message is stored by pressing the key
.
promotional image
This allows you to enable/disable the promotional image
shown on the display in normal user mode:
- ON: in normal user mode the message “Select drink”
is alternated, every 3 seconds, with the promotional
image
- OFF: in normal user mode, only the message “Select
drink” is shown
Contrast regulation
Use this function to regulate the display contrast from
min. 5% to max. 99% (default).
CurrenCy symbol
Use this function to enable the currency symbol (€, $
or £) you have set up during the credit display)
gestione menu
passWord
This is a 5-digit numerical code which is requested for
displaying all the functions of the menu.
By default, the value of this code is set to 00000
From this group of functions it is possible to enable and
set the password.
enabling the loader menu
With this function it is possible to make visible or not the
loader menu.
Using the keys
and
, you can scroll through the
items of the rst-level loader menu; the key
can be
used to modify the status of the chosen menu (ON/OFF).
advanCed menu
Allows you to enable or disable the function of requiring
a password to view all the “advanced” functions of the
Technician Menu when entering the programming mode;
the password prompt is disabled by default.
fresh breW unit data
Only if the fresh brew unit is available.
You can set up the parameters relative to fresh brew unit
1 and 2 (if available) in this group of functions.
pre-breWing time
Use this function to establish the pause time of the brew-
ing unit in tenths of a second before brewing (default 100
t/sec.)
drying time
Use this function to establish the pause time of the brew-
ing unit in tenths of a second after brewing and before
ejecting the used dose (default 100 t/sec.)
piston pressure time
Use this function to regulate the piston speed and the
pressure exerted on the dose in the brewing chamber
(default 5).

and quality.