EasyManua.ls Logo

EVOCA Opera - Page 41

EVOCA Opera
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35 05 2013 4365 00
keyboard
key <---> seleCtion
Only for machines with direct selection keyboard.
With this function it is possible to vary the order of the
selections associated with the keyboard dened by the
layout that has been set.
The display will show, in a sequence, the list of the fore-
seen selections and by pressing the destination key, the
match is stored.
verifiCation no. of seleCtion
This allows you to verify the selection number matched
to a key.
Without sugar
With this function it is possible to set all the selections as
“without sugar”.
deCaffeinated CyCle
This function acts on the selections based on instant cof-
fee. The selections are identied in the layout as unmodi-
able.
By enabling this function in all the selections based
on instant coee (if present) the powder is dispensed
before the water
For each selection based on instant coee it is however
possible to change this parameter individually.
DA CONFIGURATION
This group of functions controls all the parameters re-
lated to the operation of the machine.
date and time set
Function used to set up the current date and time.
The value is used to manage the time band and statis-
tics.
In case of power failure, the machine keeps the date and
time set up by means of a buer battery.
boiler temperature
This function allows you to set the working temperature,
in °C, of the boiler(s).
From this function, press the conrmation key
, the
temperature value ashes and it can be modied with
the keys
and
db management
This group of functions allows you to manage the opera-
tional database of the machine
db management
initialisation
This function shall be used in case of a memory data
error or if the software is replaced.
All statistic data are reset except for the general elec-
tronic counter.
When the display is set to the “Initialisation” function, you
can initialise the machine by restoring all default data.
Press the Enter key
to display the request for con-
rmation “Do you conrm?”. If you press the Enter key

once again, you will be required to enter some
parameters, i.e.:
- Country: understood as the type of basic doses for the
various selections
(e.g. IT coee = 60 cc - FR coee = 106 cc).
The “countries” made available according to models.
- lay out: a well-dened number of Button-Selection
combinations is available for selection for every single
model and type of doses (the combinations available
for every single layout are supplied by the selection
dose table supplied with the machine).
- tank: Used to dene whether water supply occurs:
0 - from the network
1 - with an internal tank
Conrm the options to display the message “Execution”
for some seconds.
save Custom db
Only for machines with a RAM expansion board.
To save a copy of the current conguration of the ma-
chine (backup) in the CPU board memory before cus-
tomising.
restore Custom db
To restore the machine conguration you have custom-
ised and saved before by means of the “Save modied
DB” function.
To restore factory settings, initialise the machine.
save db Copy
Allows you to save a copy of the current conguration of
the device (backup) on the CPU board memory before
making customizations.
db Copy time
Only in some software versions.
Allows you to set up the time when a copy of the current
conguration of the device (backup) will be saved on the
CPU board memory before making customizations.

Related product manuals