38 05 2013 4365 00
Cup turret time
Use this function to determine the rotation stop delay
time of the cup stacker to balance any inertia due to the
type of cup.
The time is expressed in tenths of a second.
energy saving
In order to save energy when the machine is not used, it
is possible to choose among the following energy saving
options:
energy saving:
with this option it is possible, in the time intervals which
are set with the function “Energy Saving Parameters”, to
suspend the service of the vending machine and switch
o or not the boiler.
The selections are not available for the whole duration of
the Energy Saving period.; the available energy saving
proles are:
- Sleep energy saving (sleep mode): with this option,
after 15 minutes of inactivity of the vending machine,
the LEDs of the door switch off and the temperature of
the boiler decreases to approx. 70 °C. When any selec-
tion button is pressed, the machine restarts the normal
operations and as soon as the operational temperature
is reached, the selections become available again.
- Soft Energy Saving (lights off only): with this option it is
possible to switch off the lighting LEDs of the keyboard
during the time intervals set by the function “Energy
Saving Parameters” while the boiler continues to work
normally. When any selection button is pressed, the
lighting of the keyboard is reactivated and the machine
immediately restarts the normal operations.
energy saving parameters
With this function it is possible to set up to 4 time bands
during which the energy saving proles will switch on
out of serviCe maChine lighting
It is possible to dene whether the lighting shall be
switched on or not when the machine is out of service
and the “Energy saving” mode is on.
set maintenanCe dispensing
With this function it is possible to establish how many
dispensing tests can be made at each door opening. By
default, the value is set to 0 and there are no limitations
on the dispensing tests.
refrigerating unit id setup
This function is available only on machines with a refrig-
erating unit.
master slave
The machine control system is arranged for the connec-
tion in series with other vending machines.
settings
This function allows you to set the hierarchies of the
master / slave1 / slave2 relationships between the con-
nected machines.
This machine can be congured as “Master”, therefore
assuming control of the second machine or as “Slave”,
therefore leaving the control to the other machine.
Furthermore, the numbers of the selections will be set,
with two digits (XX) or three digits (0XX; 9XX)
By default, the master/slave function is not enabled.
slave priCe holding
In case the Executive payment system is set in “Price
Holding” mode, with this function it is possible to set the
same mode also in the software of the slave machine.
return virtual priCe
If the payment system is set with BDV and/or Executive
protocol and for combined or virtual selections (whose
relative menus are on the slave machines), with this op-
tion it is possible to establish whether to keep (OFF) or
not (ON) the partial amount, in case the second selec-
tion/dispensing should fail.
reset minislave
With this function it is possible to reset all the settings re-
lated to the master/slave function on the slave machine.