Design and function
Machine configuration menu
099-000121-EW501
29.06.2015
91
1 Preparation
Switch off the welding machine.
Unscrew the gas nozzle from the welding torch.
Unfasten the tungsten electrode and extract.
2 Configuration
Press the or (Tetrix Classic) push-button while simultaneously switching on the welding
machine.
Release push-button.
The required parameter can now be selected using the rotary knob.
3 Adjustment/measurement
Applying slight pressure, press the welding torch with the collet against a clean, purged location on the
workpiece and then press the torch trigger for approx. 2 seconds. A short-circuit current will flow
briefly, which is used to determine and display the cable resistance. The value can be between 0
and 60 mΩ. The new value is immediately saved without requiring further confirmation. If no value is
shown on the right-hand display, then measurement failed. The measurement must be repeated.
4 Restoring welding standby mode
Switch off the welding machine.
Lock the tungsten electrode in the collet again.
Screw the gas nozzle onto the welding torch.
Switch on the welding machine
5.18.3 Power-saving mode (Standby)
The power-saving function can be activated either by pressing the button for a longer time - See 4.3
Machine control Operating elements chapter or by setting a parameter in the configuration menu (time-
based power-saving mode).
When power-saving mode is activated, both machine displays show the horizontal digit in the
centre of the display only.
Pressing any operating element (e.g. tapping the torch trigger) deactivates power-saving mode and the
machine is ready for welding again.