15
3.8.2 Set Ringing Extensions in Day mode
Format: 3 0 M N 0 #
Explanation:
M: the C.O. Line port No. M=1 - 3
N: the Ext. port No. N=1–8( N=1 means Ext.601 …… N=8 means Ext.608)
Description: In operator work mode when incoming call from No.M C.O.
line arrives and system in day mode(in default setting system in day mode),
No. N Ext. will ring.
In default setting only Ext601, 602 will ring.
Format: 3 0 M N 1 #
Description: Disable No. N Ext. ring when incoming call from No. M C.O.
line arrives.
Format: 3 0 M #
Description: Disable all Ext ring when incoming call from No. M C.O. line
arrives.
Example: Set Ext.605 and Ext.607 and EXT.608 ring when call from C.O.
line 2 arrives while the system in day mode, then input 302#, 302050#,
302070#, 302080#.
3.8.3 Set Ringing Extension n Night mode
Format: 3 1 M N 0 #
Description: In operator work mode when incoming from No. M C.O. line
arrives and system is in night mode, Ext N will ring.
In default setting only Ext 601, 602 will ring.
Format: 3 1 M N 1 #
Description: Disable No. N Ext. ring when incoming call from No.M C.O.
line arrives while system in night mode.
Format: 3 1 M #
Description: Disable all Ext ring when incoming call from No.M C.O. line
arrives while system in night mode.
Example: Set Ext.603 and Ext.605 ring when incoming call from C.O. line 2
arrives while the system is in night mode, then input 312#, 312030#,
312050#.
system in either day or night mode, that mean you can repeat to input
30MN0# or 31MN0# for 8 times.
●Before you set certain ringing extension, we suggest you’d better
disable all the Exts ring for this C.O. line.