Digital Brushless AC servo drive system - Ref.0707 MCS- 85/92
Solution. Contact Fagor Automation.
Cause. The drive does not accept the motor that has been connected to it.
Motor's power voltage is different from that of the drive it is connected
to. For example, connecting the motor FXM34.40
A.E1.000 , with A
winding (400 V AC) to drive MCS-20
L (220 V AC).
Solution. Check that the selected motor-drive combination is coherent.
Cause. One of the sine or cosine signals of the encoder has reached a peak level
lower than 150 mV.
Solution. Contact Fagor Automation.
Cause. The drive has not detected the rotor sensor.
Solution Match the selected sensor with the feedback installed and, if the error
persists, contact Fagor Automation.
E.506 Motor table missing
E.510 Incoherent combination of motor and feedback
E.605 Excessive damping of the analog signals of the
motor feedback.
E.801 Encoder not detected
+ 0.15 V
- 0.15 V