ST100 Series Flow Meter APPENDIX C - ADDITIONAL INFORMATION
Fluid Components International LLC 81
■ SendtoDevice(button)
▬ Modbus
■ Modbus(frame)
Node ID: (text box)
Mode: (drop-down list)
Baud: (drop-down list)
Data Bits: (drop-down list)
Parity: (drop-down list)
Stop Bits: (drop-down list)
□ GetfromDevice(button)
□ SendtoDevice(button)
▬ ExtendedOperationalMode
■ SystemMode(frame)
Toggle System Mode: (button)
■ ExtendedOperationalMode(frame)
Basic (radio button)
External Input Flow Adjust (EIA) (radio button)
– ExternalST100FlowInput(EFI)(radiobutton)
Auto FE Calibration Group Switching (FCS) (radio button)
External Control Group Switching (EGS) (radio button)
■ Ext.InputFlowAdjustSetup(frame)
Factor1: (text box)
Factor2: (text box)
Factor3: (text box)
Factor4: (text box)
■ Ext.ST100FlowInputSetup(frame)
– (Ext.ST100)FlowUnits:(drop-downlist)
– (Ext.ST100)FlowMin(4mA):(textbox)
– (Ext.ST100)FlowMax(20mA):(textbox)
■ GetfromDevice(button)
■ SendtoDevice(button)
■ SetSystemModeto“Running:”whenSend(checkbox)
▬ GroupSwitchSetup
■ AUTOFECalibrationGroupSwitchingSetup(frame)
■ ExternalControlGroupSwitchingSetup(frame)
● Diagnostics
▬ Status
■ Faults,FEStatus(scrollabletextbox)
■ GetfromDevice(button)
▬ FaultLog
■ Faultloglist(scrollabletextbox)
■ GetfromDevice(button)
■ ClearFaultLog(button)
■ AddtoSDCardLog(button)
▬ ScheduledTasks
■ FE#(drop-downlist)
■ InternalDelta-RResistorCheck(frame)
Mode (drop-down list)
– Day,#days,DOW(spinner)
Time (spinner)
Run Check Now (button)
■ GetfromDevice(button)
■ SendtoDevice(button)
▬ TestLogs
■ Testloglist(scrollabletextbox)
■ GetfromDevice(button)
■ ClearTestLogs(button)
■ AddtoSDCardLogs(button)
● factory
▬ FactoryParameters
■ CalibratedMin/Max(frame)
Min & Max Flow (text boxes, Std feet per second)
Min & Max Temp (text boxes, Degrees F)
Min & Max Press (text boxes, psi (g))
■ GetfromDevice(button)
■ SendtoDevice(button)
— Identication
■ General(frame)
– InternalCORES/Wversion(textbox)
Customer name (text box)
Device CO (text box)
Device S/N (text box)
– HMIS/Wversion(textbox)
■ UnitMACAddress(frame)
– MACaddress(6octets,spinnerforeach)
■ GetfromDevice(button)
■ SendtoDevice(button)
— 4-20mAFactory
■ 4-20mA#1Settings(frame)
Min DAC (4 mA) (spinner)
– MaxDAC(20mA)(spinner)
Manual DAC Counts (spinner)
Click to Output Manual (button)
■ 4-20mA#2Settings(frame)
Min DAC (4 mA) (spinner)
– MaxDAC(20mA)(spinner)
Manual DAC Counts (spinner)
Click to Output Manual (button)
■ 4-20mA#3Settings(frame)
Min DAC (4 mA) (spinner)
– MaxDAC(20mA)(spinner)
Manual DAC Counts (spinner)
Click to Output Manual (button)
■ 4-20mAInput(frame)
Raw A/D Counts (text box)
Gain (text box)