Type 03: Description of components
Valve terminal type 03 consists of individual
modules. Each module is assigned with different
functions and different elements for connection,
display and operation. The diagram below sum-
marizes the modules.
3
2 4 51
4
6
55
44
Bild 1/1: Module der Ventilinsel Typ 03
No. Modules
1 Node FB6
2 Electronic modules (input/output modules), fitted with
• digital inputs (modules with 4 or 8 inputs)
• digital outputs (modules with 4 outputs)
3 End plate left with hole for additional earth cable connection
4 Pneumatic modules (valve sub-bases) fitted with S valves:
• 5/2 single solenoid valves
• 5/2 double solenoid valves
• 5/3 mid-position valves (exhausted, pressurized, blocked)
• blanking plates S = Auxiliary pilot air
5 Pneumatic MIDI or MAXI modules:
• pressure supply with integrated exhaust (MIDI)
• intermediate air supply with integrated exhaust (MIDI)
• pressure supply adapter with/without regulator (MIDI/MAXI)
• additional air supply module (MAXI)
6 End plate right, depending on the size of the last sub-base:
• with common pneumatic tubing connections and integrated regulator
for 5 bar auxiliary pilot air (unregulated pilot air is not permitted)
• with common pneum. tubing connections, but without integrated regulator
• without common pneumatic tubing connections (only MAXI)
VIFB6 - 03/05 1. System summary
9809c 1-3