4 Electrical installation
Festo – P.BE-CPX-CMAX-SYS-EN – en 2017-09b – English 39
4 Electrical installation
4.1 Safety instructions
Warning
Danger of electric shock from voltage sources without protective measures.
For the electrical power supply, use only PELV circuits in accordance with
EN 60204-1 (Protective Extra-Low Voltage, PELV).
Also observe the general requirements of EN 60204-1 for PELV circuits.
Use only voltage sources which guarantee reliable electrical isolation of the operat
ing and load voltage in accordance with EN 60204-1.
Always connect all circuits for operating and load voltage supplies U
EL/SEN
, U
VAL
and
U
OUT
.
Through the use of PELV circuits, protection from electric shock (protection from direct and indirect
contact) in accordance with EN 60204-1 is ensured (Electrical equipment of machines. General require
ments).
ESD protection
Note
At unassigned plug connectors, there is the danger that damage may occur to the
device or to other system parts as a result of ESD (electrostatic discharge).
Seal unused connections with protective caps.
The CMAX power supply is provided via the CPX terminal (è Section 4.5).