5. Maintenance and conversion
5-21
Festo P.BE-MPA-EN en 1108e
5.3.7 Replacing the interlinking boards
MPA-S valve terminal with multi-pin plug connection
or AS interface
With the multi-pin plug connection, the electrical interlinking
module is constructed on a modular basis. Each sub-base has
its own board. The following interlinking boards are available
for the MPA-S valve terminal with multi-pin plug connection:
Interlinking board for ...
Version
one sub-base onesub-baseand
one supply plate
Type: VMPA1-MPM-EV-AB-8 Type: V MPA1 -MPM-EV-AB
-8 Only for size MPA1:
Printed circuit board for
controlling a total of 8 solenoid
coils per sub-base.
Type: VMPA1-MPM-EV-AB-4 Type: V MPA1 -MPM-EV-ABV-4 For sizes MPA1 and M PA2:
Printed circuit board for
controlling a total of 4 solenoid
coils per sub-base.
Type: VMPA2-MPM-EV-AB-2 Type: V MPA2 -MPM-EV-ABV-2 Only for size MPA2:
Printed circuit board for
controlling a total of 2 solenoid
coils per sub-base.
Tab. 5/5: Interlinking boards type VMPA-M PM-...