© Festo Didactic 655633 83
The stations of the MPS
are generally delivered
• completely assembled
• operationally adjusted as single station
• commissioned
• tested
Note
If stations are combined changes of the mechanical set-up and the position and
setting of sensors may be necessary.
The commissioning is normally limited to a visual check to ensure correct tubing
connections / wiring and supply of operating voltage.
All components, tubing and wiring is clearly marked so that all connections can be
easily re-established.
The following is required to commission the MPS
station:
• The assembled and adjusted MPS
station
• A control console
• A PLC board
• A power supply unit 24 V DC, 4.5 A
• A compressed air supply of 4 bar (400 kPa), approx. suction capacity of 50 l/min
• A PC with installed PLC programming software
6.1
Workstation