MS6-SV-...-E-10V24
70 Festo – MS6-SV-...-E-10V24 – 1310b English
Type MS6-SV-E
Switching point Approx. 50 % of p1 Fig. 11
Filling flow Adjustable through flow control valve Fig. 19
Nominal operating voltage DC [V ] 24
Permissible voltage fluctuation [%] ±10
Max. switching frequency [Hz] 0.5
Switching time off [ms] 40
Switching time on [ms] 130
Duty cycle [%] 100
Electrical connection Sub-D, 9-pin (the product may only be operated with
the related multi-pin plug sockets NECA-S1G 9-P9-MP…)
Protection class IP65 with multi-pin plug socket NECA-...
Noise level [dB(A)] 75 with silencer UOS-1
Information on material, housing Die-cast aluminium
Information on material, seal NBR
Max. current consumption [A] 0.12
1)
Protection against electric shock
(protection against direct and indirect
contact as per EN 60204-1/IEC 204)
By means of PELV power supply unit
Switching position display LED and potential-free contact
Semiconductor relay (signal contact)
–Max.voltage
– Max. continuous current
– Max. resistance in the
switched-on status
– Max. leakage current in the
switched-off stat us
[V]
[A]
[Ω]
[μA]
60
0.12
25 ( typ. 18)
1
Min. pause after exhausting [s] 1
Protection class III
Fire protection classification to UL94 V0-V2
1) During the switch on process, an increased starting current takes place sh o rt-term.
Tab. 9 General data