FT-50 Fill Level Inspector Operation Guide
2-6 Industrial Dynamics Company, Ltd. Document 40272-0700
2.
Loosen the head height lock and, using the head height adjustment
crank, adjust the head height as follows:
• If the new setting is above the previous setting, crank the head up
until the head height counter indicates you have reached the
correct height.
• If the new setting is below the previous setting, crank the head
below the new setting about 20 ticks and then back up until the
head height counter indicates you have reached the correct height.
This will eliminated any backlash in the raising mechanism.
3.
Tighten the head height lock to secure the position.
Adjusting the Conveyor Guide Rails
To accommodate the new container you may need to adjust the conveyor
guide rails. If this is required, your Service Department should instruct
you in the proper method.