Chapter 3: Using the System Software
Industrial Dynamics Company, Ltd. Document 40272-0700 3-7
Software Function Descriptions
This section contains function descriptions for each function group.
Depending upon your FT-50 machine type, machine configuration, and
options package, some of these options may not apply to your FT-50.
Fill Level Functions Group
Underfill Status
This function activates or deactivates the rejection of underfilled
containers. Deactivating this function inhibits the rejection of containers
with fill levels below the underfill threshold. It does not turn off underfill
inspection, it only stops the rejector from rejecting underfills. Underfill
and overfill can not be active simultaneously on the FT-50.
Overfill Status
This function activates or deactivates the rejection of overfilled
containers. Deactivating this function inhibits the rejection of containers
with fill levels above the overfill threshold. It does not turn off overfill
inspection, it only stops the rejector from rejecting overfills. Underfill and
overfill can not be active simultaneously on the FT-50.
Gamma Counts
The gamma count the gamma detector is currently registering.
Target Head Height
Displays the head height setting for the current container type. This
setting and the height indicated in the head height counter (Figure 1-1 on
page 1-3) should match.
Container Finish Functions Group
High Cap Status
Activates or deactivates high cap detection. High cap detection is based
on the difference between the height of the container with a properly
seated cap and height of the container with an improperly seated cap.
Missing Cap Status
Activates or deactivates missing cap detection. Missing cap detection
utilizes proximity and optical sensors to detect the presence or absence of
the cap.