FT-50 Fill Level Inspector Operation Guide
3-8 Industrial Dynamics Company, Ltd. Document 40272-0700
Smashed Bottle Status
Activates or deactivates smashed bottle detection.
Diameter Missing Cap Status
Activates or deactivates diameter missing cap detection. Diameter
missing cap detection is based on the difference between the diameter of
the container without a cap and diameter of the container with a cap.
External Reject Status
Activates or deactivates the external reject function. When activated the
FT-50 will accept the reject signal from an outside inspection source and
activate the rejector.
Counters Functions Group
The counters record operational and performance data about the FT-50
and the production line it is operating on. This data is useful for plant
performance management and for machine maintenance. Here are some
other issues you should be aware of:
• The counters are active only for those functions that are active. If you
disable a function, the associated counter (or counters) no longer
include that function in the count.
• When you reset a counter, the current count is erased. If you need the
current count, you should record it before you reset the counter
Total Throughput
Displays the total number of containers that passed through the trigger
beam. The counter automatically resets at 99,999,999.