Chapter 2: Operating Your FT-50
Industrial Dynamics Company, Ltd. Document 40272-0700 2-13
Aligning the Smashed Bottle Sensor
Figure 2-6.
Aligning the smashed bottle sensor.
The smashed bottle sensor is mounted on a upstream offset bracket
attached to the centerline trigger bracket. Therefore before you align high
cap sensor, be certain the centerline trigger bracket is aligned properly.
For more information see “Adjusting the Centerline Trigger Bracket
Height” on page 2-7.
1.
If your FT-50 is not equipped with an automatic safety shutter, you
must close the manual shutter before you proceed. For more infor-
mation see “The Safety Shutter” on page 2-3.
2.
Center a typical smashed production container under the upstream
sensor mounting bracket.
7
3
5
2
4
4
1
6
No. Description
1 Height Adjustment Lock
2Sensor beam
3 Sensor Emitter
4 Bracket Extension
5 Sensor Receiver
6 Sensor Trigger Alignment Point
7 Container Travel