FT-50 Fill Level Inspector Operation Guide
5-4 Industrial Dynamics Company, Ltd. Document 40272-0700
Maintenance Procedures
For safety, power down the equipment to be serviced before you begin
any maintenance procedure. To power down the rejector turn off the main
power switch on the junction box.
If your FT-50 is not equipped with the autoshutter feature, you should
close the manual safety shutter. For more information see “Chapter 2:
Operating Your FT-50.”
Trigger Beam and Emitter Lenses
1.
Inspect each lense for debris and damage.
2.
Clean each lense with a cotton swab, lens tissue, or a soft cloth. Do
not use paper towels because they are abrasive and can scratch the
lense.
3.
Apply several drops of medium viscosity oil to the lead screw on the
trigger raising mechanism. Be careful not to disturb the trigger raising
mechanism.
4.
Inspect the beacons for cracks in the lenses and moisture inside the
lenses. Report any problems to your Service Department.
High Cap, Missing Cap, and Smashed Bottle Sensors
1.
Inspect each sensor for debris and damage.
2.
Clean each sensor with a cotton swab, lens tissue, or a soft cloth. Do
not use paper towels because they are abrasive and can scratch the
lense.
3.
Insure that all parts are firmly attached to the mounting brackets and
locking knobs are tight. Do not disturb the position of the mounting
brackets. Report any problems to your Service Department.