EasyManua.ls Logo

Filtec FT-50 - Error Number 14; Error Number 15; Error Number 16; Error Number 22

Default Icon
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4: Diagnostics and Troubleshooting
Industrial Dynamics Company, Ltd. Document 40272-0700 4-5
Error Number 14
The gamma counts reaching the detector decreased rapidly to a value that
is 75 percent below the average count for the last eight containers. Report
this error to your Service Department.
Error Number 15
The missing cap sensor input state logic level remains high. This occurs
when two or more consecutive signals are received from the trigger beam,
which indicates containers are passing through the unit, and no signals are
received from the missing cap sensor. Report this error to your Service
Department.
Error Number 16
The trigger beam is not sensing containers. The gamma count pattern
indicates containers are passing through the gamma beam, however no
trigger signal is received. Report this error to your Service Department.
Error Number 22
This error occurs when an encoder pulse is missed. The encoder may be
failing. Report this error to your Service Department.
Error Number 23
This error occurs when an extra encoder pulse is detected. This error can
occur when the conveyor stops or starts suddenly. If this error persists,
report this error to your Service Department.
Error Number 24
Report this error to your Service Department.
Error Number 25
Report this error to your Service Department.
Error Number 27
Containers are passing the inspection station, but the encoder is not
sending pulses: at least 5 consecutive inspection triggers occurred without
sensor transition. Report this error to your Service Department.