FT-50 Fill Level Inspector Operation Guide
4-2 Industrial Dynamics Company, Ltd. Document 40272-0700
Diagnostic Errors
This section contains a Diagnostic Error Code List to help you quickly
identify error codes and Diagnostic Error Descriptions to provide
additional information on the error.
The amber warning beacon on top of the inspection head signals an alarm
or error condition by blinking rapidly. To view the error code:
1.
Press the
Key 6
to view the error code in the LCD.
2.
Press the
Arrow Key
to scroll through the error description and to
clear the error condition. When you clear the error, the message resets
to zero.
Diagnostic Error Codes Listing
The following list contains the FT-50 error codes. Depending upon your
machine type, some of these errors may not apply to your FT-50. For
more information see “Diagnostic Error Descriptions” on page 4-4.
0 No Diagnostic Error
* 2 Rejector Status Is Off
5 Consecutive Reject Queue Error
6 Consecutive Reject Timing Error-Missed Encoder Pulse
10 Fill Level Detection Error-Exceeded Consecutive Reject Limit
11 Missing Cap Detection Error-Exceeded Consecutive Reject Limit
12 High Cap Detection Error-Exceeded Consecutive Reject Limit
13 Gamma Counts Below Reject Threshold Error
14 Gamma Detector Error
15 Missing Cap Sensor Error
16 Trigger Beam Error
17 Encoder Sensor Error
18 Slat Rejector Backup Sensor Is Blocked
22 Encoder Pulse Missed
23 Extra Encoder Pulse Detected
24 High Resolution Encoder Minimum Distance Error
25 High Resolution Encoder Minimum Time Error
* 27 High Resolution Encoder Failure