Chapter 5: Maintenance Procedures
Industrial Dynamics Company, Ltd. Document 40272-0700 5-5
The FT-50 Housing
1.
Inspect for damage to metal housing and for wear on the cover
gaskets.
2.
Check to be sure the cover is securely tightened
3.
Clean using a non-caustic nonabrasive soap, water, and a soft brush.
Rinse with clean water. Report any problems to your Service
Department.
Do not wash with a high pressure nozzle.
Do not steam clean
Pressure Regulator and Air Filter
1.
Inspect the polycarbonate sediment bowl for cracks and abrasion.
2.
Clean and drain the air filter sediment bowl.
3.
Inspect the air filter in the inspection head for clogging. Report any
problems to your Service Department.
External Wiring
1.
Check the external wiring between the sensors and the FT-50 for
damage. Check all connections carefully to be sure they are not loose.
2.
Check that insulating sleeves are in place. Report any problems to
your Service Department.
Replacing the Rejector Pad
The actual lifespan of the rejector pad depends upon the operating condi-
tions of your production line. Inspect the pad weekly and replace if worn,
cracked, or hardened. Refer to your rejector manual for instructions on
replacing the pad. Report any problems to your Service Department.
Servicing the Regulator and Coalescing Air Filters
Servicing the air filter consists of cleaning and/or replacing the air filter,
sediment bowl, and gasket. You can obtain replacement parts for these
items from the air controls manufacturer.
Warning
Turn off all power to your system before attempting any repair procedure.

Table of Contents