FT-50 Fill Level Inspector Operation Guide
5-6 Industrial Dynamics Company, Ltd. Document 40272-0700
1.
Turn off the air flow control valve and depressurize all connected air
lines.
2.
Remove and clean the sediment bowl. If your unit contains a polycar-
bonate bowl, inspect it for cracking or cloudiness; if present, replace
it. Report any problems to your Service Department.
Warning
Cracked or cloudy polycarbonate bowls can explode when repressurized,
causing serious injury.
3.
Clean other parts using soap and water.
4.
Dry the bowl and other parts, and blow out internal passages in the
body using filtered, dry compressed air.
5.
Using filtered, dry compressed air, blow through the filter element
from inside to outside to dislodge surface contaminants. If the filter
element is plugged, replace it.
6.
Apply a light coating of Dow Corning 44M grease (or equivalent) to
the bowl gasket, and reassemble. Report any problems to your
Service Department.