Chapter 4: Diagnostics and Troubleshooting
Industrial Dynamics Company, Ltd. Document 40272-0700 4-7
Error Number 51
A container passed without any encoder pulses. This can be caused by:
blocking the trigger with the line stopped
encoder failure
trigger reflections
line jams
This error condition is low priority and will not cause the warning beacon
to flash during high priority only operation. If this error persists, report
this error to your Service Department.
Error Number 52
A container passed the trigger in less than 10 ms. This can be caused by
trigger reflections or line jams. If this error persists, report this error to
your Service Department.
Error Number 53
The reject watchdog detected a queue error. If this error occurs repeatedly,
call IDC technical support.
Error Number 54
This error displays the reject queue count. If this error occurs repeatedly,
call IDC technical support.
Error Number 58
An abnormally large container was detected. The reject delay encoder
count exceeded the current encoder count. This condition is generally
caused by line jams. If this error occurs continuously, the rejector may be
installed to near the trigger. Report this error to your Service Department.
Error Number 61
The reject delay position at the rejection queue output exceeded the
current encoder count. If this error occurs repeatedly, call IDC technical
support.
Error Number 66
A fill level reject was detected while the fill level status was turned off.
Turn the fill level status on to correct this condition.