14 MS-9200UDLS/E/C Manual — P/N 52750:F 7/26/2010
Product Description Features and Options
• Touchtone/Rotary dialing
• Programmable Make/Break Ratio
• EIA-232 Printer/PC interface (variable baud rate)
• 80-character LCD display (backlit)
• Real-time clock/calendar with daylight savings time control
• History file with 1,000 event capacity
• Advanced fire technology features:
Automatic drift compensation
Maintenance alert
Detector sensitivity test capability (NFPA 72 compliant)
Automatic device type-code verification
Point trouble identification
• Waterflow selection per module point
• Alarm verification selection per detector point
• Walktest, silent or audible
• PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant)
• Silence inhibit timer option per NAC
• Autosilence timer option per NAC
• Continuous, March Time, Temporal or California code for main circuit board NACs with two-
stage capability
• Selectable strobe synchronization per NAC
• Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules, ACS
annunciators or ANN-80 Remote annunciator
• Auto-program (learn mode) reduces installation time. Reports two devices set to the same
address
• Password and key-protected nonvolatile memory
• User programmable password
• Fully programmable from local keypad or optional keyboard
• Optional PK-CD (contains PS-Tools utility) for local or remote Upload/Download of program
and data
• Compatible with Fire-Lite’s newer series devices in LiteSpeed and CLIP mode (refer to SLC
Wiring Manual for a list of compatible addressable devices)
• Compatible with legacy Fire-Lite 300 Series devices in CLIP mode only (refer to the SLC
Wiring Manual for a list of compatible addressable devices)
• Optional 4XTMF module (conventional reverse polarity/city box transmitter)
• Optional ZNAC-92 Class A converter module for NACs
• ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators
are used):
ANN-80 Remote Annunciator
ANN-80C Remote Indicator (Canadian Applications)
ANN-I/O LED Driver
ANN-S/PG Printer Module
ANN-RLY Form-C Relay Module
ANN-LED Annunciator Module annunciates alarm, trouble and supervisory (required for
Canada and emergency signaling)
ANN-RLED Annunciator Module annunciates alarms only
• Automated activation of the ACC-25/50(ZS/T) Audio-Command-Center