Maintenance Instructions
Seite/Page 112 - Kaptitel/Chapter 7: Maintenance Instructions 16.1.15
Caution: Burn hazard!Generator and coolant can be hot during and after
operating.
Wear personal protective equipment. (Gloves, protective
goggles, protective clothing and safety shoes)
• Assure generator against accidental start.
• Open the generator casing.
• Pull the oil dipstick out of the check rail.
• Clean oil dipstick.
• Put the oil dipstick back into the check rail and wait for 10 seconds.
• Pull the oil dipstick out of the check rail and read off the oil-level at the lower end of the stick.
Fig. 7.6-1: Oil dipstick - SampleOil dipstick
The oil-level is to be checked by means of the oil dipstick.
The prescribed filling level must not cross the „Max“-mark.
We recommend an oil-level of 2/3.
Sample picture
Fig. 7.6-2: Oil dipstickOil dipstick EA 300 Engine
The oil-level is to be checked by means of the oil dipstick.
The prescribed filling level must not cross the „Max“-mark.
We recommend an oil-level of 2/3.
Sample picture
Oil should be refilled, if the oil-level is under 1/3 between the minimum and the maximum mark.
Fischer Panda recommends an oil-level of 2/3 between the minimum and the maximum mark.
If the oil-level is under the MIN-mark, check how many operating hours went by since the last oil change, by means
of your service manual or an existing oil change tag. - with operating hours between 50 and 150 hours it is only
necessary to refill oil. See „Refilling oil“ on page 2.
• with 150 operating hours or more the oil should be changed (See your generators’ service table)
• if the oil-level is under the minimum mark by less than 50h, there might be a technical problem! In that case, we
recommend going to a shop or a Fischer Panda service point.
• if the oil is cloudy or even „creamy“, coolant might have mixed with the oil. See a garage or a Fischer Panda service
point immediately.
2/3 Suggestion
Oil Max.
Oil Min.
Oil Max.
Oil Min.
2/3 Suggestion