Inverter Panda PMGi 8000 / PMGi 10000
16.1.15 Kapitel/Chapter 16: Inverter Panda PMGi 8000 / PMGi 10000 - Seite/Page 215
1) Peak Strom darf den 3-fachen Nennstrom erreichen
1) Peak current is allowed to reach 3 times of the nominal current
Frequenz
Frequency
Nominale Frequenz
Nominal Frequency
Fréquence nominale
60 Hz +/-2 %
Regulierung
Regulation
Réglage
4%
Stabilität (Kurzeitig) (30sec))
Stability (short term (30sec))
Stabilité (courte durée (30s))
3%
Stabilität (Langzeit (4h))
Stability (Long term (4h))
Stabilité (longue durée (4h))
3%
Krestfaktor
Crestfactor
Facteur de crête
3:1
Empfohlene Absicherung
Recommend protection Fuse
Sécurisation
recommandée
80 A
Empfohlener
Kabelquerschnitt
Recommend cable cross
Section de câble recommandée
25 mm²
Wassertemperatur max.
Water temperature max.
40 °C
Umgebungstemperatur max.
Ambient temperature
60 °C
PMGi 10000 120 V