User’s manual FlexGain Plex, V2
Version 1.3 58 from 99
where
HH are hours (00…23),
MM are minuted (00…59),
SS are seconds (00…59).
The <TIME> command without any parameters displays the current time.
To display the help information, enter <TIME /H>.
Example:
PLEX2_01_FMM>TIME 11.26.15
PLEX2_01_FMM>TIME
Current time is: 11.26.17
<V35CLKMODE> command.
The <V35CLKMODE> command sets the clock mode on the V.35 interface.
Command syntax:
<V35CLKMODE> [CODIR | CONTRDIR]
where
CODIR sets codirectional clock mode, which coincides with the direction of
transmission from DTE to DCE;
CONTRDIR sets contradirectional clock mode, which does not coincide with the
direction of transmission from DTE to DCE;
The <V35CLKMODE> command without any parameters displays the current clock
mode of the V.35 interface.
To display the help information, enter <V35CLKMODE /H>
Example:
PLEX2_01_FMM>V35CLKMODE CODIR
PLEX2_01_FMM>V35CLKMODE
V35 stream clock mode:Coodirectional mode.
<V35CLKTX> command.
This command allows the user to set the element of the clock (the leading edge or
the trailing edge of the pulse) from which the transmitter of the V.35 interface will be
synchronized.
Command syntax:
<V35CLKTX> [NORMAL | INVERS]
where
NORMAL sets synchronization from the leading edge of the clock pulse;
INVERS sets synchronization from the trailing edge of the clock pulse.