EasyManua.ls Logo

FlexGain PLEX - Page 68

Default Icon
99 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User’s manual FlexGain Plex, V2
Version 1.3 68 from 99
PLEX2_06_CM>EVENT LOG
20.04.05 16.19.06 Module program reset.
19.04.05 16.05.11 Module program reset.
18.04.05 14.25.01 Module program reset.
18.04.05 12.00.32 Module program reset.
18.04.05 10.34.46 Module program reset.
18.04.05 10.19.48 Module program reset.
15.04.05 10.05.32 Module program reset.
14.04.05 16.59.53 Module program reset.
14.04.05 16.59.10 Module program reset.
14.04.05 16.53.07 Module program reset.
PLEX2_06_CM>EVENT CLEAR
Event log................
Cleared.
PLEX2_06_CM>
<FTSPAD> command.
The <FTSPAD> sets/maps the padding of free time slots. The default value of the
padding is FF.
The <FTSPAD> command without any parameters displays the configured
parameters.
Command syntax:
<FTSPAD> [PCM1|PCM2 PV]
where
PCM1, PCM2 are notations of Е1 streams.
PV is the Padding Value (hex is one byte).
To display the help information, enter <FTSPAD /H>
Example:
PLEX2_01_CM>FTSPAD PCM1 AA
PLEX2_01_CM>FTSPAD
PCM-stream free timeslot padding values:
PCM1: AAh
PCM2: FFh
PCM3: FFh
<MOVECAS> command.
This command allows mutual replacement of TS No. 16 of the E1 stream with any
other TS, except for TS No. 0. Transmission of line signaling in first time slots provides the
operation of voice interfaces over the streams with the TS number less than 16. By default,
the time slot for CAS is 16.
The <MOVECAS> command without any parameters displays the number of CAS.