A Menu structure FLUXUS WW
UMFLUXUS_WWV1-1EN, 2018-02-28 127
selection of the unit of measurement for the physical quantity
input of the duration over which a floating average of the measured val-
ues has to be determined
range: 1...600 s
activation of the data logger
activation of the measured values transmission to a PC or a printer via a
serial interface
selection of the storage rate for storing measured values in the data log-
ger
This display will only be indicated if Output Options\Store
Meas.Data and/or Serial Output are activated.
input of the storage rate if Storage Rate = EXTRA is selected
range: 1...43 200 s (= 12 h)
Current loop
activation of a current output
This display will only be indicated if the current output has been installed
in Special Funct.\SYSTEM settings\Proc. outputs.
selection whether the sign of the measured values is to be considered for
the output
This display will only be indicated if Current Loop is activated.
input of the lowest/highest measured value to be expected for the current
output
The values are assigned to the lower/upper limit of the output range.
These displays will only be indicated if Current Loop is activated.
input of the error value delay, i.e. the time interval after which the error
value is transmitted to the output in case no valid measured values are
available
This display will only be indicated if Special Funct.\SYSTEM set-
tings\Dialogs/Menus\Error-val. delay = EDIT is selected.
Alarm output
activation of an alarm output
This display will only be indicated if an alarm output has been installed in
Special Funct.\SYSTEM settings\Proc. outputs.
selection of the switching condition (func), the holding behavior (typ)
and the switching function (mode) of the alarm output
This display will only be indicated if Alarm Output is activated.
selection of the physical quantity to be monitored
This display will only be indicated for R1 if Alarm Output is activated.
INIT-resis-
tant
Volume in:
m3/h
Damping
10 s
Store Meas.Data
no >YES<
Serial Output
no >YES<
Storage Rate
Once per 10 sec.
Storage Rate
1s
Current Loop
I1: no >YES<
Meas.Values
>ABSOLUT< sign
Zero-Scale Val.
0.00 m3/h
Full-Scale Val.
300.00 m3/h
Error-val. delay
10 s
Alarm Output
no >YES<
R1=FUNC<typ mode
Function: MAX
R1 Input:
Volume flow