FLUXUS WW 7 Installation
30 UMFLUXUS_WWV1-1EN, 2018-02-28
7.2.3 Pipe installation
Installation on a 2'' pipe
The pipe mounting kit is fixed to the pipe using a shackle.
Fix the pipe mounting plate (2) and the instrument mounting plate (3) to the pipe using the nuts (4) and the shackle (1)
(see Tab. 7.1 and Fig. 7.2).
Use the screws to fix the transmitter to the instrument mounting plate (see Fig. 7.3).
Installation on a pipe > 2"
The pipe mounting kit is fixed to the pipe using tension straps.
Insert the tension straps into the holes (5) of the pipe mounting plate (2) and the instrument mounting plate (3) (see Tab.
7.1 and Fig. 7.4).
Fix the pipe mounting plate and the instrument mounting plate to the pipe using the tension strap.
Use the screws to fix the transmitter to the instrument mounting plate (see Fig. 7.3).
Tab. 7.1: Parts of the mounting kit
number designation
1shackle
2 pipe mounting plate
3 instrument mounting plate
4nut
5 tension strap