FLUXUS WW 7 Installation
30 UMFLUXUS_WWV1-1EN, 2018-02-28
7.2.3 Pipe installation
Installation on a 2'' pipe
The pipe mounting kit is fixed to the pipe using a shackle.
• Fix the pipe mounting plate (2) and the instrument mounting plate (3) to the pipe using the nuts (4) and the shackle (1)
(see Tab. 7.1 and Fig. 7.2).
• Use the screws to fix the transmitter to the instrument mounting plate (see Fig. 7.3).
Installation on a pipe > 2"
The pipe mounting kit is fixed to the pipe using tension straps.
• Insert the tension straps into the holes (5) of the pipe mounting plate (2) and the instrument mounting plate (3) (see Tab.
7.1 and Fig. 7.4).
• Fix the pipe mounting plate and the instrument mounting plate to the pipe using the tension strap.
• Use the screws to fix the transmitter to the instrument mounting plate (see Fig. 7.3).
Tab. 7.1: Parts of the mounting kit
number designation
1shackle
2 pipe mounting plate
3 instrument mounting plate
4nut
5 tension strap
Fig. 7.2: Installation of the instrument mounting plate
Fig. 7.3: Installation of the transmitter