Setup
5
2. To configure a schedule when motion detection will be activated, click Setup next to
Working Protocol.
Select the day you would like to configure by clicking the Setup buttons. You can
apply the same schedule to multiple days using the checkboxes.
Configure up to 6 time periods when motion detection will be activated.
Click Save. Repeat the steps above if you would like to apply a different schedule to
different
3. Under Anti-dither, enter the anti-dither time. After a motion event occurs and motion
stops, if motion is detected within the anti-dither time, the system continues the motion
event and includes the new motion within the first event, rather than creating a new
motion event.
#LX400038; r. 1.0/18537/18537; en-US
36

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR IP Series and is the answer not in the manual?

FLIR IP Series Specifications

General IconGeneral
Sensor TypeUncooled microbolometer
Weather ResistanceYes
Video CompressionH.264, MJPEG
PowerPoE (IEEE 802.3af)
Spectral Range7.5 – 13 μm
Thermal Sensitivity< 50 mK
Video OutputEthernet
IP RatingIP66
Resolution320 × 240 pixels
Frame RateUp to 30 Hz (varies by model)