Issue 13 CWT Compact Touch Installation and Maintenanace Manual Page 45
• You are registered as a user in Cale WebOffice and have been given the
proper privileges for access times, opening frequencies, compartment
(cabinet, pedestal or both), etc.
• You identify yourself by inserting an access card in the card reader and
entering an optional PIN code at the keyboard (CWTC S3A with keyboard
and CWTC Touch). In a CWTC S3A without keyboard and in terminals
without a card reader, you place a special ID card against an RFID reader
mounted in the plastic casing in the right bottom corner.
NOTE:
After you have opened the upper door, the lock will be closed again after a 15
second time out to save power. Because the terminal now is in the service mode
you cannot prove your identity and get the necessary privilege to open the door
again. Instead you have to press an Open Upper Door key shown in the start
page of the service menu to open the lock mechanism again.
The pedestal door lock also has a 15 second time out, but you can still run the
normal application with the upper door closed and open the lower door lock as
usual.
Master key
The electronic lock system also provides an opening alternative in case of power
failure, software failure or communication disturbances. Inside the electronic lock
there is a regular lock as well. A mechanical master key is used for emergency
access, but the protective plate has to be pushed up manually first by means of a
small screwdriver, paper clip, or similar.
Latches
The electronic lock has a relay operated latch mechanism that prevents anyone
from opening the key lock unless the person can prove his identity.
Note:
The minimum voltage required for proper operation of the electronic locks is 11.1
V at room temperature (20 ˚C).
Configuration of the E-locks
The upper and the lower E-locks are of the same type. Each lock is a DIP-switch
whose setting tells the system if the lock is mounted in the cabinet or pedestal.
The E-locks are connected to the CPU board (Connector J16) board
Please note that if an upgrade from mechanical to electronic lock is desired, the
locking bar also needs to be replaced.