snapInterval
Interval for snap picture
triggerInterval
Interval for trigger alarm again,P.s.The true value of
triggerInterval time is the value of the cgi get add 5s.
scheduleN
N(0-6), alarm schedule
Note
Example
/cgi-bin/CGIProxy.fcgi?cmd=getHumidityAlarmConfig&usr=admin&pwd=
setHumidityAlarmConfig
Function
Set Humidity Alarm Config
privilege
admin
Usage
/cgi-bin/CGIProxy.fcgi?cmd=setHumidityAlarmConfig
Param
isEnable
0
disable
1
enable
linkage
Motion alarm linkage
( bit7| bit3 | bit2 | bit1 | bit0 )
bit0:Ring
bit1:Send mail
bit2:Snap picture
bit3:Record
bit7:Push to
phone
topLimit
Top Humidity
lowerLimit
Lower Humidity
snapInterval
Interval for snap picture
triggerInterval
Interval for trigger alarm again,P.s.The true value
of triggerInterval time is the value of the cgi set
add 5s.
scheduleN
N(0-6), alarm schedule
Return
None
Note
Example
/cgi-bin/CGIProxy.fcgi?cmd=setHumidityAlarmConfig&isEnable=1&linkage=1
29&topLimit=40&lowerLimit=20snapInterval=2&triggerInterval=5&schedule0=
1023&schedule1=1023&schedule2=1023&schedule3=1023&schedule4=1023&sc
hedule5=1023&schedule6=1023&usr=admin&pwd=