Do you have a question about the Frecon PV Series and is the answer not in the manual?
Notes regarding product illustration, modifications, and customer support.
Details on the inverter's identification label and its components.
Technical specifications for AC220V and DC310V input products.
Visual representation and dimensions for PV100 and PV200 series.
Wiring diagrams and steps for setting up PV panel power.
Wiring diagrams for connecting to grid or generator power.
Guidance on connecting VFD with single-phase motors.
Explanation of main and control circuit terminals on the inverter.
Overview of essential system and frequency-related function parameters.
In-depth explanation of PV pump special set function codes (H00 group).
Fault due to overcurrent during acceleration and its solutions.
Fault due to overcurrent during deceleration and its solutions.
Fault due to overcurrent at constant speed and its solutions.
Fault due to overvoltage during acceleration and its solutions.
Fault due to overvoltage during deceleration and its solutions.
Fault due to overvoltage at constant speed and its solutions.
Fault related to low bus voltage and protection measures.
Faults related to short circuits and their troubleshooting.
Fault due to open phase on input and related troubleshooting.
Fault due to open phase on output and related troubleshooting.
Fault due to motor overload and its troubleshooting.
Fault due to inverter overload and its troubleshooting.
Fault due to external input protection and its reset.
Fault related to overheating and cooling measures.
Fault caused by memory chip damage or version incompatibility.
Procedure for cancelling self-identification process.
Troubleshooting steps for self-identification failures.
Fault due to communication timeout and parameter settings.
Fault when PID feedback is lost during operation.
Fault indicating the programmed running time has been reached.
Errors during parameter upload process.
Errors during parameter download process.
Faults related to the braking unit and resistor.
Fault due to temperature sensor disconnection or failure.
Fault when inverter load is too low.
Fault related to current limit and load conditions.
Fault when the soft-start relay is not closed.
Error due to EEPROM version mismatch.
Hardware detected overcurrent fault.
Hardware detected overvoltage fault.
Fault related to hydraulic probe malfunction.
Warning for low light conditions and its parameters.
Warning for full water level and its conditions.
| Series | PV Series |
|---|---|
| Output Frequency | 50Hz/60Hz |
| Protection Features | DC Reverse Polarity Protection, Over Current Protection, Over Voltage Protection, Temperature Protection |
| Operating Temperature Range | -25°C to +60°C |
| Storage Temperature Range | -40°C to 70°C |
| Humidity | 0-95% (Non-condensing) |
| Communication | RS485, Wi-Fi (Optional) |
| Display | LCD |
| Certifications | CE |